CYCLAIR® 180

The CYCLAIR® 180 is a portable differential pressure device used to apply negative pressure to confined and difficult-to-access areas.

Category:
  1. General Details

    The CYCLAIR® 180 is a portable differential pressure device used to apply negative pressure to confined and difficult-to-access areas. 

    For protecting people and their natural environment from the spreading of radioactive particles. For processing alpha and beta radiation particles. 

  2. Operation

    + Negative pressure is applied to the work area to prevent contaminants from spreading 

    + The CYCLAIR® 180 is equipped with a 110 V single-phrase fan with a speed controller to ensure an extraction air flow rate of 180 cfm 

    + The contaminated air is sucked in via flexible ducts (118 in length) fitted with swivel connections. 

    + The air is purified by a “nuclear”-type HEPA filter. 

    + It is coated in decontaminable paint. 

    + The CYCLAIR® 180 has been designed so that it can be easily carried over the shoulder (strap) or by hand (handle). It weights less than 38 lbs 

    + It is designed to guarantee total airtightness 

  3. Use Case

     + Direct dynamic containment 

    The CYCLAIR® 180 is used to apply negative pressure and to ensure filtering of dispersed pollutants (valves). 

    + Static/dynamic containment 

    The CYCLAIR® 180 is used to apply negative pressure to an airlock used as a containment system for a work area 

    + Radiation protection during dismantling phases 

    The CYCLAIR® 180 can be used when carrying out minor procedures or on sites where operators require protection. 

  4. Features

    As standard:

    + A needle pressure gauge for continuously measuring clogging of the filter 

    + Cable with a A16 connector provides a 110 V single-phase power supply to the equipment. 

    + This supply voltage is used to automatically restart the device in the event of a power failure 

    + An On/Off button controls the fan 

    + A potentiometer varies the fan speed to ensure the required flow of air 

    + Fitted with absorbers, it can be placed on the floor without risking any damage 

    + A handle is used to carry the device about on site 

    + A strap enables the device to be carried over the shoulder 

    + The device is connected via a swivel connector (Ø 6,69 in). 

    As an option:

    + A trolley on castors can be used to move the CYCLAIR® 180 around even more easily 

    + An airtightness report following an uranine test. 

  5. Specifications

    Nominal Flow: 180cfm

    Fan Power: 0.17 kW

    Sound Pressure: 52.7 dB(A) at 3 m

    Overall Weight: 38lbs

    Dimensions:

    Diameter: 15 in

    Length: 31.5 in

    URANINE purification coefficient (*) : > 5000

    (*): absolute filter: DOP and NacL efficiency > 99.99% 

  6. Related Products