12/24 Battery Pack

  1. General Details

    Great For Emergency Response or Routine Sampling!

    Use 12V for long term sampling or 24V for High Volume Grab Sampling

    Features:

    • 2000 Peak Amps
    • Use at 12 volts or 24 volts
    • Enough power to sample for a variety of situations
    • Heavy duty cable and slip connector or jumper cable clamps
    • Powered by two 12 volt sealed, lead-acid batteries
    • 12 volt systems use the batteries in parallel, 24 volt systems in series
    • DC outlet powers a variety of 12 volt accessories
    • Weighs 36 lbs. 16”Hx7”Dx12”W
    • Recharge from any 120 volt AC or 12V DC power supply; 12 volt charger is included

    Power Without The Backache! 

    Power ANYWHERE!

    • Emergency lighting
    • Back-up power
    • Any 12 or 24v Device
    • Built in lighter style adapter

    All Position Use

    • Sealed Lead Acid Genesis Battery won’t leak
    • Transport, use or store in any position

    Holds Charge for Months

    • Use test button to check for charge status
  2. Specifications

    RADēCO tested the unit in two configurations under two different voltage selections.

    Media
    Voltage Selected
    Start Air Flow
    Finish Air Flow
    Total Time Sampled
    CP100/95% Paper (1)

    12 VDC

    1.36 CFM

    .8 CFM

    2 hrs 5 mins

    CP100/95% Paper (1)

    24 VDC

    2.9 CFM

    .8 CFM

    1 hr 16 mins

    Gelman AE 47 mm (1)

    24 VDC

    3 CFM

    .5 CFM

    1 hr 20 mins

    Gelman AE 47 mm (2)

    12 VDC

    1.4 CFM

    .6 CFM

    3 hrs 45 mins

    Gelman AE 47 mm (2)

    24 VDC

    2.8 CFM

    1 CFM

    1 hr 29 mins

    (1) An H-809 DC was used.

    (2) An H-810 DC was used.